Cytek Biosciences Logo

Cytek Biosciences

Full Spectrum Flow Cytometry Systems | Discover the Advantages | Cytek Biosciences

Who is Cytek Biosciences?

Conventional flow cytometers have difficulty distinguishing fluorochromes with highly overlapping peak emissions, severely limiting fluorochrome choice and multiplexing capability. Using full spectrum flow cytometry, our systems detect the entire fluorochrome emission, allowing researchers to run panels of up to 40 colors and beyond without sacrificing data resolution. By making bigger panels possible, spectral flow cytometry provides researchers more information from one tube and reduces the amount of tubes needed in an assay. This saves precious sample and reagent, reduces sample preparation and acquisition time, and reduces operating costs, allowing labs to run more efficiently. With Full Spectrum Profiling™, gone is the need to check and swap optical filters depending on the assay.

This company is:

Service provider
Educational institution
Manufacturer

Fremont, United States

101-250 Employees

Founding year: 1992



Products & services of Cytek Biosciences

Product 
    APC Anti-Mouse CD366 (TIM-3) (RMT3-23) | Cytek Biosciences
   image
Product

Verified

APC Anti-Mouse CD366 (TIM-3) (RMT3-23) | Cytek Biosciences

TDS | SDS The RMT3-23 antibody reacts with mouse CD366 which is also known as Tim-3 (T cell immunoglobulin and mucin domain containing protein-3). Tim-3 is expressed on activated monocytes, macrophages, dendritic cells, and mast cells. Additionally, Tim-3 is found on Th1 lymphocytes and functions as an inhibitory receptor involved in the maintenance of immune homeostasis and self tolerance. Name APC Anti-Mouse CD366 (TIM-3) (RMT3-23) Cat. No. 20-5870 Alternative Names Havcr2, TIM3, Timd3 Gene ID 171285 Clone RMT3-23 Isotype Rat IgG2a, κ Reactivity Mouse Format APC Application Flow Cytometry

Product 
    cFluor® V505 Anti-Human HLA-DR (L243) | Cytek Biosciences
   image
Product

Verified

cFluor® V505 Anti-Human HLA-DR (L243) | Cytek Biosciences

The L243 monoclonal antibody binds to the human HLA-DR antigen, a 36-kDa alpha heavy chain and a 27-kDa beta light chain heterodimeric cell surface glycoprotein in transmembrane major histocompatibility complex 2 (MHC II) family (1)(2). HLA-DR, also known as human leukocyte antigen DR isotype, is present on the surface of antigen-presenting cells, including B cells, dendritic cells, macrophages, monocytes and activate T cells. MHC class II regulates the immune system by playing a critical role in binding and presenting antigen-derived peptides to peptide-MHC II-specific CD4 T cells(3). The antibody was conjugated to a fluorophore and purified by affinity chromatography. PRODUCT DETAILS Clone:                  L243 Reactivity:          Human, African Green, Baboon, Chimpanzee, Cynomolgus, Dog (Canine), Marmoset, Rhesus, Squirrel Monkey, Tamarin Format:               cFluor® V505  Isotype:               Mouse IgG2a, κ Tested Dilution:  5 μL / test Application:        Flow Cytometry Storage:               2-8°C and protected from Light. Do not freeze Formulation:      Phosphate-buffered saline, pH 7.2, containing 0.09% sodium azide and 0.2% BSA (BSA Country of Origin USA). Data Sheets:       TDS SDS   RECOMMENDED USAGE Each lot of this antibody is quality control tested using flow cytometric analysis. For flow cytometric staining, the suggested use of this reagent is 5 µL per 1 million cells in a staining volume of 100 µL. If whole blood is analyzed, then use 5 µL per 100 µL. It is recommended that users titrate the antibody to obtain the optimal result for their specific application. Please briefly centrifuge the reagent vial before use. Use appropriate personal protective equipment per the product safety data sheet when using this product.        Spectral signature of cFluor® V505 from a Cytek® Aurora 5 laser system equipped with 355 nm, 405 nm, 488 nm, 561 nm and 640 nm lasers using CytekAssaySettings.  REFERENCES Korman, A J et al. 1982. Proc Natl Acad Sci U S A. 79(19):6013-6017 Shackelford DA, et al. 1982. Immunol Rev. 66:133-87 Walseng E, et al. 2008. J Biol Chem. 23;283(21):14717-27  

Product 
    redFluor™ 710 Anti-Human HLA-DR (L243) | Cytek Biosciences
   image
Product

Verified

redFluor™ 710 Anti-Human HLA-DR (L243) | Cytek Biosciences

TDS | SDS The L243 antibody reacts with a member of the human MHC Class II antigens, HLA-DR. The HLA-DR antigen is expressed on B lymphocytes, activated T lymphocytes, activated NK cells, monocytes, macrophages, other antigen presenting cells and progenitor cells. The L243 antibody is specific to an epitope on the alpha subunit of the heterodimeric HLA-DR protein and binds a different epitope than the LN3 antibody clone. It does not cross-react with HLA-DP or HLA-DQ. This antibody is reported to be cross-reactive with non-human primates including Chimpanzee, Cynomolgus, Rhesus and Baboon. Please choose the appropriate format for each application. Name redFluor™ 710 Anti-Human HLA-DR (L243) Cat. No. 80-9952 Gene ID 3122 Clone L243 Isotype Mouse IgG2a, κ Reactivity Human Cross Reactivity Chimpanzee, Cynomolgus, Rhesus, Baboon, Squirrel Monkey, African Green Monkey Format redFluor™ 710 Application Flow Cytometry

View all products


Keywords

Health Care
Navigational, Measuring, Electromedical, and Control Instruments Manufacturing
Biotechnology
Medical Device
Manufacturing
Computer and Electronic Product Manufacturing
Analytical instruments

Industries

Health Care
Manufacturing
Biotechnology
Science and Engineering

Use Cases of Cytek Biosciences

text-slider-1

Deep Immune Cell Profiling With Flow Cytometry | Cytek Biosciences

-


Contact of Cytek Biosciences

City: Fremont

State: California

Country: United States



Frequently asked questions (FAQ) about Cytek Biosciences

The company Cytek Biosciences is located in Fremont, California, United States. It's worth noting that the company may has more corporate locations

As of the latest available information Cytek Biosciences has around 101-250 employees worldwide.

Cytek Biosciences was founded in 1992

The company Cytek Biosciences has it's main focus in the industries of Health Care, Manufacturing, Biotechnology, Science and Engineering

Based on the founding year and the amount of employees the company Cytek Biosciences seems to be a Medium-Sized Company at the current state. Note that over time that status can change

Competitors of Cytek Biosciences

BD Biosciences Logo

BD Biosciences

India

1-10 Employees

1967

Dx BioTech Inc. Logo

Dx BioTech Inc.

Canada

1-10 Employees

2017

Fluorofinder Logo

Fluorofinder

United States

11-50 Employees

2008

Particle Metrix GmbH Logo

Particle Metrix GmbH

Germany

11-50 Employees

2004

AbD Serotec Logo

AbD Serotec

United States

1981

BioForm Solutions Logo

BioForm Solutions

United States

1-10 Employees

2014

Quest Innovations Logo

Quest Innovations

Netherlands

11-50 Employees

1998

Core Quantum Technologies Logo

Core Quantum Technologies

United States

1-10 Employees

2012


Suitable topics for Cytek Biosciences

Topics which have been searched by others and may be interesting for you: